Brf Viborg 1, Malmö.

Pipe Relining Syd sealed the association’s masonry ventilation ducts with our liner. The camera image the next morning showed a smooth, round duct.

A garden roller is rolled over the liner in the attic to spread the polymer.
Location
Malmö
Property
Brf Viborg 1, a building from 1948
Ducts
Masonry ventilation ducts
Installer
Pipe Relining Syd
Material
Liner from Linervent
Time
October 2026

Old masonry ducts leak on the way up.

Masonry ducts of that age often have a rough, cracked inside. The air then leaks out before it reaches the roof.

The liner was impregnated with a garden roller.

The polymer is so viscous that an ordinary relining roller drags the felt along with it. Instead, Pipe Relining Syd poured the polymer into one end of the liner and pushed a garden roller of up to 50 kg forward until the felt was saturated.

The liner was then inverted into the duct from the roof. According to the installation manual, the open time is normally 45 minutes at 23 °C and 50 percent relative humidity. Ten degrees warmer normally halves it, and the trip up to the roof counts towards that time.

The duct was smooth the next morning.

The camera image the next morning showed a smooth, round duct from the inside.

Source: our LinkedIn posts from 21 October ↗ and 4 November 2026 ↗.